Shaker RMS

APM-Technische-Ausstattung_066

Technical data
  • Peak force 17660 N
  • Frequency range 5−2000 Hz
  • Displacement pk-pk ±12.7 mm
  • Max. load 300 kg
  • Connectable horizontal table
Areas of application
  • Vibration and shock tests
  • Transportation tests
  • Simulation of in-use stresses 
Shaker LDS

APM_9-2015_02

Technical data
  • Peak force 22200 N
  • Frequency range DC –3000 Hz
  • Displacement pk-pk ±25.4 mm
  • Max. load 350 kg
  • With a temperature range from -70°C to +150°C
  • Connectable temperature chamber
Areas of application
  • Vibration and shock tests
  • Transportation tests
  • Simulation of stresses during use
  • All tests can be carried out with various temperatures applied
1000 liter temperature chamber

APM-Technische-Ausstattung_070

Technical data
  • Temperature range -70°C to +150°C
  • Heating rate 3 K/min on average
  • Cooling rate +150°C to +20°C: 6 K/min
  • Cooling rate +20°C to -60°C: 4 K/min
  • Usable testing space 1040 x 880 x 670 mm
  • Max. test specimen weight 200 kg
  • Connectable with shaker
  • Additional compressed air dryer available
Areas of application
  • Temperature tests
  • Testing of storage and operating conditions
  • Accelerated ageing by means of cycle tests
600-liter climatic chamber

APM-Technische-Ausstattung_058

Technical data
  • Temperature range -70°C to +180°C
  • Heating rate 2.5 K/min on average
  • Cooling rate 2.5 K/min on average
  • Climatic range +10°C to +90°C with 10% rh to 98% rh
  • Dew point range +5°C to +89.5°C
  • Usable testing space 645 x 645 x 625 mm
  • Max. test specimen weight 100 kg
  • Additional compressed air dryer available
Areas of application
  • Climatic tests
  • Testing of storage and operating conditions
  • Accelerated ageing by means of cycle tests
  • Humidity aging
500-liter stress-screening chamber

APM-Technische-Ausstattung_057

Technical data
  • Temperature range -70°C to +180°C
  • Heating rate 10 K/min on average
  • Cooling rate 10 K/min on average
  • Climatic range +10°C to +95°C with 10% rh to 98% rh
  • Dew point range I +7°C to +94°C
  • Dew point range II -10°C to +7°C
  • Usable testing space 640 x 625 x 515 mm
  • Max. test specimen weight 100 kg
  • Additional compressed air dryer available
Areas of application
  • Climatic tests
  • Testing of storage and operating conditions
  • Accelerated ageing by means of cycle tests
  • Humidity aging
Climatic chamber

APM-Technische-Ausstattung_059-2

Technical data
  • 64-liter climatic chamber
  • Temperature range -70° to +180°C
  • Heating rate 4 K/min on average
  • Cooling rate 4 K/min on average
  • Climatic range +10°C to +93°C with 10% rh to 95% rh
  • Dew point range +5°C to +93°C
  • Extended dew point range -20°C to +93°C
  • Additional compressed air dryer available
  • Usable testing space 430 x 390 x 330 mm
  • Max. test specimen weight 10 kg per rack, max. 50 kg total weight
Areas of application
  • Climatic tests
  • Testing of storage and operating conditions
  • Accelerated ageing by means of cycle tests
  • Humidity aging
Walk-in climatic chamber

APM-Technische-Ausstattung_061

Technical data
  • Temperature range -65°C to +85°C
  • Heating rate 1 K/min on average
  • Cooling rate 0.4 K/min on average
  • Climatic range +10°C to +70°C with 10% rh to 95% rh
  • Dew point range +5°C to +69°C
  • Usable testing space 2100 x 1800 x 1900 mm
  • Door 950 x 1900 mm
  • Chamber floor load capacity 10000 N/m2
  • Additional compressed air dryer available
Areas of application
  • Climatic tests
  • Testing of storage and operating conditions
  • Accelerated ageing by means of cycle tests
  • Humidity aging
  • Testing of large devices
  • Application testing at high and low temperatures
Rain test system

APM-Technische-Ausstattung_075

Technical data
  • Test system for IPX3 and IPX4
  • Configuration: sprinkler in accordance with EN 60529
Areas of application
  • Testing for watertightness
  • Rain from above
  • Spray water from all sides
Water jet system

 APM-Technische-Ausstattung_080-3

Technical data
  • Test system for IPX5 and IPX6
Areas of application
  • Testing for water-tightness
  • Water jets
  • Strong water jets
Immersion tube

APM-Technische-Ausstattung_077-2

Technical data
  • Equipment for IPX7 and IPX8
  • Diameter 380 mm
  • Maximum immersion depth 1500 mm
Areas of application
  • Testing for water-tightness
  • Water-tightness of housing when submerged
Chest-style salt spray chamber

APM-Technische-Ausstattung_073

Technical data
  • Testing space 70 x 50 cm; depth 60 cm
  • Testing space volume including lid 600 l
  • With climate function
  • Chamber for neutral salt-spray tests
Areas of application
  • Testing for corrosion resistance
  • Comparative testing of anti-corrosion coatings
Vacuum chamber

APM-Technische-Ausstattung_079

Technical data
  • Pressure range 54 mbar to approx. 1100 mbar
  • Chamber diameter 890 mm
  • Chamber length 800 mm
  • Electrical feedthroughs
  • USB connection in chamber
  • Optical window
  • Field-attachable flange for individual data cables (on request)
Areas of application
  • Vacuum tests
  • Testing of device functionality at high altitudes